
GEYA
GY-SVG 220V–800V Three-phase SVG
Էլեկտրաէներգիայի որակ։ GY-SVG 220V–800V Three-phase SVG։ Մոդելի տեխնիկական տվյալներ և գնառաջարկ ԲիգՎոլտից։
| Բրենդ | GEYA |
| Ապրանքային խումբ | Էլեկտրաէներգիայի որակ |
Տեխնիկական բնութագրեր
| Voltage Platform | Available Capacity per Module | Grid Configuration |
| AC 220V | 3 / 5 / 7 / 10 / 17 / 25 / 37 / 50 / 75 kvar | 3P3W / 3P4W |
| AC 380V | 5 / 10 / 15 / 20 / 35 / 50 / 75 / 100 / 150 kvar | 3P3W / 3P4W |
| AC 500V | 90 kvar | 3P3W / 3P4W |
| AC 690V | 120 kvar | 3P3W / 3P4W |
| AC 800V | 150 kvar | 3P3W only |
| Voltage Platform | Operating Voltage Range | Rated Capacity per Module | Grid Configuration | Function Selection |
| 220V | AC 220V (-20% ~ +20%) | 3 / 5 / 7 / 10 / 17 / 25 / 37 / 50 / 75 kvar | 3P3W / 3P4W | Reactive / Reactive + Unbalance |
| 380V/400V | AC 380V/400V (-20% ~ +20%) | 5 / 10 / 15 / 20 / 35 / 50 / 75 / 100 / 150 kvar | 3P3W / 3P4W | Reactive / Reactive + Unbalance |
| 500V | AC 500V (-20% ~ +20%) | 90 kvar | 3P3W / 3P4W | Reactive / Reactive + Unbalance |
| 690V | AC 690V (-20% ~ +15%) | 120 kvar | 3P3W / 3P4W | Reactive / Reactive + Unbalance |
| 800V | AC 800V (-20% ~ +15%) | 150 kvar | 3P3W only | Reactive only |
| Parameter | Specification |
| Model Series | GY-SVG-220V / 380V / 500V / 690V / 800V |
| Operating Frequency | 50 Hz / 60 Hz (45 Hz ~ 63 Hz auto-sensing) |
| Parallel Units | Unlimited |
| Overall Efficiency | ≥ 97% |
| Switching Frequency | 16 kHz (220V / 380V) | 12.8 kHz (500V / 690V / 800V) |
| Reactive Compensation Rate | ≥ 99% |
| Unbalance Compensation | Unbalance degree after compensation ≤ 5% |
| Transient Response Time | < 50 µs |
| Full Response Time | < 10 ms |
| Control Core | DSP (TI 28335) + CPLD full-digital control, three-level topology |
| Overload Capability | 1.2× rated for 60 seconds |
| Noise Level | ≤ 60 dB (220V) | ≤ 65 dB (380V – 800V) |
| Communication | 2× RS485 (Wi-Fi supported) |
| Protection Functions | Overload, software / hardware overcurrent, grid over- / under-voltage, grid voltage imbalance, power-supply failure, over-temperature, frequency anomaly, short-circuit protection |
| Installation | Rack-mounted / Wall-mounted |
| Cable Entry | Rear entry (rack) / Top entry (wall-mount) |
| Protection Rating | IP20 (IP54 customizable) |
| Cooling Method | Forced air cooling, independent air duct design |
| Altitude | < 2000 m (derate above 2000 m per GB/T 3859.2) |
| Ambient Temperature | -10 to +50 °C (capacity derating ≤ 30% above 40 °C) |
| Relative Humidity | ≤ 90%, no condensation at monthly minimum 25 °C |
| Pollution Degree | Class III |
| No. | Model | Voltage (V) | Grid Wiring | Frequency (Hz) | Control Chip | Capacity (kvar) |
| 1 | GY-SVG-5k | 220 | 3P3W / 3P4W | 50/60 | 28335 | 5 |
| 2 | GY-SVG-7k | 220 | 3P3W / 3P4W | 50/60 | 28335 | 7 |
| 3 | GY-SVG-10k | 220 | 3P3W / 3P4W | 50/60 | 28335 | 10 |
| 4 | GY-SVG-17k | 220 | 3P3W / 3P4W | 50/60 | 28335 | 17 |
| 5 | GY-SVG-25k | 220 | 3P3W / 3P4W | 50/60 | 28335 | 25 |
| 6 | GY-SVG-37k | 220 | 3P3W / 3P4W | 50/60 | 28335 | 37 |
| 7 | GY-SVG-50k | 220 | 3P3W / 3P4W | 50/60 | 28335 | 50 |
| 8 | GY-SVG-75k | 220 | 3P3W / 3P4W | 50/60 | 28335 | 75 |
077 555 707 ↗